It is often the last question before someone approves a quote, asked almost apologetically: "And what will it do to my electricity bill?" The short answer is: not much. A sign with 3 metres of LED strip inside, lit 8 hours a day all year, uses about 54 kWh. At the French regulated rate of early 2026, that is a little over 10 euros a year. Here is where those figures come from, so you can redo the sum for your own sign.
What actually uses the power
In a Color Neon sign, the acrylic backing and the silicone tube use nothing at all. The power goes into the LED strip hidden inside, the one that follows every letter and every curve of the design. A longer outline means more strip. More strip means more power.
Our 12 V strip was measured by its manufacturer on a one-metre sample: 6.16 watts per metre. The data sheet also gives 7.2 W per metre, but that is the nominal value, a ceiling on paper. We use the measured figure because it comes from a real strip, switched on.
One caveat, to be fair with you. That figure is taken at the strip. Your meter will see a little more, because the adapter loses some energy as heat. Our sheet does not put a number on that loss, so we do not make one up.
The number on the adapter is not what you use
This is the mix-up we see most. The adapter that comes with the sign says 36 W or 60 W, depending on the size. Some people multiply that by their hours of use and get a fright.
That number is the most the adapter can deliver, not what it delivers. We always pick one bigger than needed, so it never runs above 75 % of its rating and stays cool. A sign with 3 metres of strip on a 36 W adapter draws about 18 W. Not 36.
The sum, in three steps
Take the length of strip in your sign and multiply it by 6.16: that gives you watts. Multiply by the hours it is on each day, then by 365, and divide by 1,000: that gives you kWh a year. Then multiply by the price per kWh on your bill.
The table does it for three common lengths. For the price we used 0.1940 euro per kWh. That is the French regulated Base tariff (6 kVA, tax included) published by the CRE, the French energy regulator, for the change of 1 February 2026. It moves every February and August, and outside France your rate will be different anyway. Keep the kWh, then put your own price at the end.
| Strip in the sign | 4 h a day | 8 h a day | 12 h a day |
|---|---|---|---|
| 1.5 m (9.24 W) | 13 kWh, €2.62 | 27 kWh, €5.23 | 40 kWh, €7.85 |
| 3 m (18.48 W) | 27 kWh, €5.23 | 54 kWh, €10.47 | 81 kWh, €15.70 |
| 5 m (30.80 W) | 45 kWh, €8.72 | 90 kWh, €17.45 | 135 kWh, €26.17 |
So how much strip is in your sign? It depends on the design more than on the size. Joined-up handwriting has lots of loops. A logo made of a few simple strokes sometimes needs less than you would think. In one recent order of five signs, the lengths ran from 1.5 m to 5.7 m. If you want the figure for your own project, ask for it with your quote.
To keep the sum at hand, we put it on one page: download the calculation sheet (PDF).
Turn it down, switch it off at night
The remote that comes with the sign is also a dimmer. The percentage keys set the brightness, and a sign turned down uses less power. In a living room in the evening, people often end up dimming it without thinking about it. It glares less, and to be frank it looks better that way.

The other habit is the switch. A sign left on all night in an empty room is electricity for nobody. A timer plug, or a power strip with its own switch, sorts that out.
Our view
For a decorative sign lit for a few hours in the evening, power use should not weigh on your choice. It matters when the sign stays on late every day: a bar, a shop, a reception area. There, a timer and a slightly simpler design do more than any setting.
If you are still working out the budget, our article on what a custom neon sign costs, line by line goes through it. Before the sign goes up, check the socket and the cable route. And if you already have an idea, you can draw it in the configurator.